FDA regulatory consultant for medical device companies. Provides 510(k)/PMA/De Novo pathway guidance, QSR (21 CFR 820) compliance, HIPAA assessments, and device cybersecurity. Use when user mentions FDA submission, 510(k), PMA, De Novo, QSR, premarket, predicate device, substantial equivalence, HIPAA medical device, or FDA cybersecurity.
What this skill does
# FDA Consultant Specialist
FDA regulatory consulting for medical device manufacturers covering submission pathways, Quality System Regulation (QSR), HIPAA compliance, and device cybersecurity requirements.
## Table of Contents
- [FDA Pathway Selection](#fda-pathway-selection)
- [510(k) Submission Process](#510k-submission-process)
- [QSR Compliance](#qsr-compliance)
- [HIPAA for Medical Devices](#hipaa-for-medical-devices)
- [Device Cybersecurity](#device-cybersecurity)
- [Resources](#resources)
---
## FDA Pathway Selection
Determine the appropriate FDA regulatory pathway based on device classification and predicate availability.
### Decision Framework
```
Predicate device exists?
├── YES → Substantially equivalent?
│ ├── YES → 510(k) Pathway
│ │ ├── No design changes → Abbreviated 510(k)
│ │ ├── Manufacturing only → Special 510(k)
│ │ └── Design/performance → Traditional 510(k)
│ └── NO → PMA or De Novo
└── NO → Novel device?
├── Low-to-moderate risk → De Novo
└── High risk (Class III) → PMA
```
### Pathway Comparison
| Pathway | When to Use | Timeline | Cost |
|---------|-------------|----------|------|
| 510(k) Traditional | Predicate exists, design changes | 90 days | $21,760 |
| 510(k) Special | Manufacturing changes only | 30 days | $21,760 |
| 510(k) Abbreviated | Guidance/standard conformance | 30 days | $21,760 |
| De Novo | Novel, low-moderate risk | 150 days | $134,676 |
| PMA | Class III, no predicate | 180+ days | $425,000+ |
### Pre-Submission Strategy
1. Identify product code and classification
2. Search 510(k) database for predicates
3. Assess substantial equivalence feasibility
4. Prepare Q-Sub questions for FDA
5. Schedule Pre-Sub meeting if needed
**Reference:** See [fda_submission_guide.md](references/fda_submission_guide.md) for pathway decision matrices and submission requirements.
---
## 510(k) Submission Process
### Workflow
```
Phase 1: Planning
├── Step 1: Identify predicate device(s)
├── Step 2: Compare intended use and technology
├── Step 3: Determine testing requirements
└── Checkpoint: SE argument feasible?
Phase 2: Preparation
├── Step 4: Complete performance testing
├── Step 5: Prepare device description
├── Step 6: Document SE comparison
├── Step 7: Finalize labeling
└── Checkpoint: All required sections complete?
Phase 3: Submission
├── Step 8: Assemble submission package
├── Step 9: Submit via eSTAR
├── Step 10: Track acknowledgment
└── Checkpoint: Submission accepted?
Phase 4: Review
├── Step 11: Monitor review status
├── Step 12: Respond to AI requests
├── Step 13: Receive decision
└── Verification: SE letter received?
```
### Required Sections (21 CFR 807.87)
| Section | Content |
|---------|---------|
| Cover Letter | Submission type, device ID, contact info |
| Form 3514 | CDRH premarket review cover sheet |
| Device Description | Physical description, principles of operation |
| Indications for Use | Form 3881, patient population, use environment |
| SE Comparison | Side-by-side comparison with predicate |
| Performance Testing | Bench, biocompatibility, electrical safety |
| Software Documentation | Level of concern, hazard analysis (IEC 62304) |
| Labeling | IFU, package labels, warnings |
| 510(k) Summary | Public summary of submission |
### Common RTA Issues
| Issue | Prevention |
|-------|------------|
| Missing user fee | Verify payment before submission |
| Incomplete Form 3514 | Review all fields, ensure signature |
| No predicate identified | Confirm K-number in FDA database |
| Inadequate SE comparison | Address all technological characteristics |
---
## QSR Compliance
Quality System Regulation (21 CFR Part 820) requirements for medical device manufacturers.
### Key Subsystems
| Section | Title | Focus |
|---------|-------|-------|
| 820.20 | Management Responsibility | Quality policy, org structure, management review |
| 820.30 | Design Controls | Input, output, review, verification, validation |
| 820.40 | Document Controls | Approval, distribution, change control |
| 820.50 | Purchasing Controls | Supplier qualification, purchasing data |
| 820.70 | Production Controls | Process validation, environmental controls |
| 820.100 | CAPA | Root cause analysis, corrective actions |
| 820.181 | Device Master Record | Specifications, procedures, acceptance criteria |
### Design Controls Workflow (820.30)
```
Step 1: Design Input
└── Capture user needs, intended use, regulatory requirements
Verification: Inputs reviewed and approved?
Step 2: Design Output
└── Create specifications, drawings, software architecture
Verification: Outputs traceable to inputs?
Step 3: Design Review
└── Conduct reviews at each phase milestone
Verification: Review records with signatures?
Step 4: Design Verification
└── Perform testing against specifications
Verification: All tests pass acceptance criteria?
Step 5: Design Validation
└── Confirm device meets user needs in actual use conditions
Verification: Validation report approved?
Step 6: Design Transfer
└── Release to production with DMR complete
Verification: Transfer checklist complete?
```
### CAPA Process (820.100)
1. **Identify**: Document nonconformity or potential problem
2. **Investigate**: Perform root cause analysis (5 Whys, Fishbone)
3. **Plan**: Define corrective/preventive actions
4. **Implement**: Execute actions, update documentation
5. **Verify**: Confirm implementation complete
6. **Effectiveness**: Monitor for recurrence (30-90 days)
7. **Close**: Management approval and closure
**Reference:** See [qsr_compliance_requirements.md](references/qsr_compliance_requirements.md) for detailed QSR implementation guidance.
---
## HIPAA for Medical Devices
HIPAA requirements for devices that create, store, transmit, or access Protected Health Information (PHI).
### Applicability
| Device Type | HIPAA Applies |
|-------------|---------------|
| Standalone diagnostic (no data transmission) | No |
| Connected device transmitting patient data | Yes |
| Device with EHR integration | Yes |
| SaMD storing patient information | Yes |
| Wellness app (no diagnosis) | Only if stores PHI |
### Required Safeguards
```
Administrative (§164.308)
├── Security officer designation
├── Risk analysis and management
├── Workforce training
├── Incident response procedures
└── Business associate agreements
Physical (§164.310)
├── Facility access controls
├── Workstation security
└── Device disposal procedures
Technical (§164.312)
├── Access control (unique IDs, auto-logoff)
├── Audit controls (logging)
├── Integrity controls (checksums, hashes)
├── Authentication (MFA recommended)
└── Transmission security (TLS 1.2+)
```
### Risk Assessment Steps
1. Inventory all systems handling ePHI
2. Document data flows (collection, storage, transmission)
3. Identify threats and vulnerabilities
4. Assess likelihood and impact
5. Determine risk levels
6. Implement controls
7. Document residual risk
**Reference:** See [hipaa_compliance_framework.md](references/hipaa_compliance_framework.md) for implementation checklists and BAA templates.
---
## Device Cybersecurity
FDA cybersecurity requirements for connected medical devices.
### Premarket Requirements
| Element | Description |
|---------|-------------|
| Threat Model | STRIDE analysis, attack trees, trust boundaries |
| Security Controls | Authentication, encryption, access control |
| SBOM | Software Bill of Materials (CycloneDX or SPDX) |
| Security Testing | Penetration testing, vulnerability scanning |
| Vulnerability Plan | Disclosure process, patch management |
### Device Tier Classification
**Tier 1 (Higher Risk):**
- Connects to network/internet
- Cybersecurity incident could cause patient harm
**Tier 2 (Standard Risk):**
- All other connected devices
### Postmarket Obligations
1. Monitor NVD and ICS-CERT for vulnerabilities
2. Assess applicability to device components
3. Develop and test patches
4. Communicate with customers
5. Report Related in General
modeling-omnistudio-epc-catalog
IncludedSalesforce Industries CME EPC product-modeling skill for Product2-based catalog creation. Use when creating EPC products, configuring product attributes, building offer bundles with Product Child Items, or reviewing EPC DataPack JSON metadata for product catalog changes. TRIGGER when: user creates or updates Product2 EPC records, AttributeAssignment payloads, AttributeMetadata/AttributeDefaultValues, Offer bundles, or ProductChildItem relationships. DO NOT TRIGGER when: designing OmniScripts/FlexCards/Integration Procedures (use building-omnistudio-omniscript, building-omnistudio-flexcard, or building-omnistudio-integration-procedure), implementing Apex business logic (use generating-apex), or troubleshooting deployment pipelines (use deploying-metadata).
relationship-science-coach
IncludedUse this skill for direct, practical adult relationship coaching: couples conflict, repair, trust, marriage, dating, flirting, attachment patterns, emotional connection, sex, desire differences, eroticism, kink negotiation, affection, love languages, breakups, and long-term passion. Draw on Gottman, EFT and Hold Me Tight, attachment science, modern sex research, Perel, Nagoski, Kerner, Schnarch, Love and Stosny, and flexible love-language tools. Be concrete and low-hedge. Redirect only for imminent danger, abuse, coercive control, minors, non-consent, self-harm, stalking, or medical/legal/psychiatric decisions.
building-sf-integrations
IncludedSalesforce integration architecture and runtime plumbing with 120-point scoring. Use this skill to set up Named Credentials, External Credentials, External Services, REST/SOAP callout patterns, Platform Events, and Change Data Capture. TRIGGER when: user sets up Named Credentials, External Services, REST/SOAP callouts, Platform Events, CDC, or touches .namedCredential-meta.xml files. DO NOT TRIGGER when: Connected App/OAuth config (use configuring-connected-apps), Apex-only logic (use generating-apex), or data import/export (use handling-sf-data).
venue-templates
IncludedAccess comprehensive LaTeX templates, formatting requirements, and submission guidelines for major scientific publication venues (Nature, Science, PLOS, IEEE, ACM), academic conferences (NeurIPS, ICML, CVPR, CHI), research posters, and grant proposals (NSF, NIH, DOE, DARPA). This skill should be used when preparing manuscripts for journal submission, conference papers, research posters, or grant proposals and need venue-specific formatting requirements and templates.
let-fate-decide
IncludedDraws the 12 Houses of the Zodiac Tarot spread to inject entropy into planning when prompts are vague, ambiguous, or casually delegated. Interprets the spread to guide next steps. Use when the user says 'let fate decide', 'YOLO', 'whatever', 'idk', or other nonchalant phrases, makes Yu-Gi-Oh references, or when you are about to arbitrarily pick between multiple reasonable approaches. Prefer over ask-questions-if-underspecified when the user's tone is casual or playful rather than precision-seeking.
net-ops
IncludedCross-platform network troubleshooting (Windows, macOS, Linux) via local or remote shell. Use for: DNS broken, can't resolve hostnames, nslookup/dig works but apps fail, NRPT, WFP, scutil, /etc/resolver, systemd-resolved, /etc/resolv.conf, NetworkManager, VPN DNS leak residue (ProtonVPN/Mullvad/WireGuard/AnyConnect), AV/firewall blocking DNS or DoH, Tailscale DNS interaction, intermittent connectivity, remote diagnostics over SSH.